Count stock
Count physical stock and reconcile it to the record.Updated Nov 5 2026
Who this is for
Warehouse staff count parts on the shelf. A warehouse lead or inventory controller sets up the counts and closes them. Accounting relies on the counts for the value of stock on the books.
Applies to
Why it matters: picking, planning and costing all assume Cetec's quantities are right. A regular count finds the errors before a short pick or a year-end write-off does.
-
Create the cycle count
- Open
Warehouse > Cycle Count > Cycle Count List(the screen is headed Cycle Count) and clickCreate New. - Pick the
Locationto count. - Choose what to count: type the
Number of Parts(it starts at 20), and narrow them withSelection Method,ABC Code,Min Value,Bins LikeorCommodity Code. To count particular parts, pick them inPrcpartand setNumber of Partsto match. Parts that already have an open count, or no stock in the location, are left out. - If no one should move stock while you count, set
Lock Inventory Transactions?toLock WarehouseorLock Bins. Locking keeps people from changing that stock while you count. Cetec unlocks it when you close the count. - Click
Create. Cetec opens the new count. If it shows Cycle Count Created But No Parts Matched Criteria!, nothing matched what you chose. Add parts by hand withAdd Parts, or create the count again with wider choices. - On the count, pick the counter in
Assigned Toand clickAssign. Cetec shows Cycle Count {number} assigned to {user}.
- Open
-
Enter the counted quantities
- On the cycle count, click
Print Allif you want count sheets to take to the shelves. - Find each part and bin, count the shelf, and type the number in
Actual Shelf Qty. The box starts at 0, so type a number in every row you set, even when the shelf matches. Count only what is on the shelf; Cetec adds back anything picked to orders. For serialized or piece-tracked parts, click(Pieces/Serials)on the row and count each piece. - Pick a
Reason Codefor the row, such as Cycle Count or Miscount. To use one reason for every row, pick it in the box under theReason Codeheading. - Click
Seton the row. Cetec shows Count set for {part} in {bin}. and the row greys out with the time inLast Updated. Please select a reason code before setting the count. means the row has no reason. Pick one and clickSetagain. - To set every row that has a quantity and reason, click
Set All ({n})and confirm; it sets rows already set again too.Set Allskips serialized and piece-tracked parts. - To see what is left to count, set
View Rows with StatustoNot Updatedand clickSubmit.
- On the cycle count, click
-
Close the count
- On the cycle count, check that
View Rows with Statusset toNot Updated(thenSubmit) shows nothing left. - Click
Close. Cetec unlocks the warehouse or bins and returns to the Cycle Count list. The list shows open counts only; remove theStatusfilter to find the closed one. - If you need to correct a closed count, open it and click
Reopen.
- On the cycle count, check that
Other ways to do this
Count the whole warehouse
A full physical inventory of one warehouse, split between several counters.
- Open
Warehouse > Cycle Count > Full Inventoryand clickStart Full Inventory. - In the form, pick the
Location, type theNumber of Parts Per Userand theNumber of Users, narrow withMinimum Part ValueorInventory Typeif you need to, and tickLock Inventory Transactionsto lock the warehouse. - Click
Start Full Inventoryin the form, and stay on the page until it finishes. Cetec shows New Inventory Started and makes one count per counter. - Each counter enters their quantities as in Enter the counted quantities.
- On the full inventory, close each count, then click
Close.