How To Perform a Full Inventory Count

Count every part in a warehouse (or a slice of it), hand the counting out as assignments, enter what each counter found, and close the count when every assignment is done.

Updated Nov 9 2026

How To Perform a Full Inventory Count

Allow external media cookies to watch this video.

Before you start

  • Warehouse > Cycle Count > Full Inventory needs the Warehouse role. Anyone you assign a count to needs it too.
  • Every counted row needs a Reason Code. The codes come from the InvShortageReason table (see Add a reason code).
  • Each row you set changes the stock at once. Closing an assignment or the full inventory only finishes it.
  • Starting a full inventory builds the assignments from the stock in the warehouse at that moment. Cetec's own warning on the start window asks that nobody else works in the system while it runs.
  1. Start the full inventory

    1. Go to Warehouse > Cycle Count > Full Inventory. The page is headed Full Inventory and lists earlier counts (ID, Created On, Warehouse, Assigned To, Total Num Bins, Total Num Parts, Num Bin Changed, Num Parts Changed, Active). To find an old one, click the filter search bar (Filter or search…), pick Location, Creation Date From or Creation Date To, and click Apply (n).
    2. Click Start Full Inventory at the top of the page. The Start Full Inventory window opens.
    3. Choose the Location (warehouse) to count. It is required.
    4. Set Number of Parts Per User to the number of parts each assignment should hold. Cetec cuts the parts into assignments of that size, in order of stock value, lowest first. Leave it at 0 to put everything in one assignment.
    5. Leave Number of Users at 0. (Above 0 the count is built bin by bin, ignores Number of Parts Per User and Sort by Primary Bin, and this window has no way to split the bins, so everything lands in one assignment.)
    6. Set Minimum Part Value to skip low-value parts. A part is left out when the stock you hold of it is worth less than this. It starts at 0, so nothing is skipped.
    7. Pick the Inventory Type: All Parts, FIG Only (parts with a BOM), Raw Materials Only or ABC Code - A to ABC Code - D.
    8. Optional: tick Sort by Primary Bin to order the assignments by each part's primary bin.
    9. Click Start Full Inventory and wait. Don't refresh or leave the page. Cetec opens the new Full Inventory number page and shows New Inventory Started.
  2. Hand out the assignments

    1. On the Full Inventory number page, the Progress bar shows how many bins are counted, and the table lists one row per assignment: ID, Created On, Warehouse, Assigned To, Bin Prefix, Total Num Bins, Total Num Parts, Num Bins Changed, Num Parts Changed and Updated.
    2. Every assignment starts with you. To give one to someone else, pick their name in that row's Assigned To list and click Submit (it saves every change you made on the page).
    3. To see what is left, set Status to Not Updated, or View Rows Assigned To to one person, and click Submit.
  3. Count an assignment

    1. Click an assignment's ID. The assignment (Inventory Assignment number) opens with one row per part and bin. If it opens on the classic screen, click Use New Version under the filters.

    2. Count each bin. In Actual Shelf Qty type what is on the shelf. Shelf Qty is what Cetec expects; stock picked to work orders is shown in WIP QTY, and Total Bin Qty is the two added together.

    3. Pick a Reason Code for the row. To use one code for every row, pick it in the box under the Reason Code heading.

    4. Click Set on the row. Cetec shows Count set for part in bin., greys the row out and fills Last Updated. To set every row that has a quantity and a reason, click Set All (n) instead and confirm.

    5. For a part tracked by pieces or serial numbers, click Pieces/Serials on its row and count each piece in the window that opens.

    6. For paper counting, click Print All, or Print on one row.

    7. Click Close and confirm Are you sure you want to close this assignment? Rows you did not set keep their quantities unchanged. Cetec takes you to the Cycle Count List, so reopen the full inventory from Warehouse > Cycle Count > Full Inventory for the next assignment.

  4. Close the full inventory

    1. On Warehouse > Cycle Count > Full Inventory, click the ID of your count. Check that Progress shows every bin counted and that no assignment has Updated set to No.
    2. Click Close (below Submit, beside the Add Stock (Non PO) button) and confirm Are you sure you want to close this Full Inventory?
    3. Cetec closes the full inventory and every assignment in it, unlocks any bins the count locked, and returns you to the list, where the count's Active column now reads No.
  5. Add a reason code

    1. Go to Admin > Maintenance > Data Maintenance, filter Data Type for InvShortageReason (type it and press Enter), click Apply (1), and click it. The page Data Maintenance For InvShortageReason opens.
    2. Click Add Record. Cetec saves an empty row at once.
    3. Fill in the row's Name and Description, leave Active set to Active, and tick No Inv Change if the code means the count found no change.
    4. Click Submit.
    5. Reload the assignment page; the new code is in Reason Code.