How To Create a BOM
Create the assembly as a part with BOM? ticked, add its components on the Edit Revision BOM screen, then check it on the BOM Overview.Updated Nov 9 2026
Before you start
- Every component must already exist as a part in Cetec; Cetec won't add a part number it can't find.
- Create Part is on the Part List (Parts > Lists, open to the User role).
- Edit BOM in a part's left menu needs the Can Edit BOM function (Manager, Engineer or Can Edit BOM by default; the Block Edit Part role takes it away). Revisions needs Can Edit Revisions (Manager, Doc Control or Engineer by default); without it Revisions is greyed out. Admins always have both.
-
Create the BOM part
- Go to Parts > Lists > Part List (the page is headed Parts) and click Create Part at the top right of the page. The Create Part window opens.
- Fill in the fields:
- PRC (required) – choose the PRC (part class) the assembly belongs to.
- Part (required) – the part number after the PRC, without the PRC itself: Cetec puts the PRC in front (PRC SUB and Part 1402-01 make SUB1402-01; typing SUB1402-01 would make SUBSUB1402-01). Once a PRC is chosen, the box shows the last part number created in it (Last - …) as a guide.
- Location (required) – starts filled with your default selling location.
- Part Description – optional.
- Revision – optional name for the first revision (for example A). Leave it empty for an unnamed revision.
- BOM? – tick Create as BOM.
- Click Create. Cetec shows Part Created and opens the new revision's Edit Revision BOM screen.
-
Add the components
- On the Edit Revision BOM screen (Cetec opens it after Create; later, open the part and click BOM DATA > Edit BOM in its left menu), find the Add new component row under the table.
- Enter the component:
- Comp # – leave it at 0 to take the next number.
- Prcpart – search for the component part.
- Work Loc – the work location it's used at, if you use them.
- Qty Per Top – how many go into one assembly (defaults to 1).
- Reference Designator – optional.
- Click Add. Cetec shows Bom line added successfully and the line appears in the table. Repeat for each component.
- To change lines already in the table (quantity, scrap factor, comments and so on), edit them in the table and click Update under the table. The table is wide: Update and Delete are at the right end, so scroll right to reach them.
- To remove lines, click the red cross in each line's Info/Delete column (the last column) so it turns red, then click Delete and Ok in Are you sure you want to delete this BOM line? (The tick box on each line is Rev Req'd, not a selection box.)
To add many at once, click Show Batch Component Add, enter one component per line as prcpart,qty per top, click Check, review the list, and click Commit. Check only checks the format, not that the parts exist. If Commit shows Prcpart not found, the lines above the unknown part were still added: reload the page and check the table before you commit again, or you'll add them twice. To change the list after Check, click Cancel and start again.
To copy another BOM's components, click Show Copy from BOM/Rev. This overwrites the current revision's BOM with the components of the BOM/revision you pick.
-
Check the BOM
- Open the assembly's part record: on the Part List, click the filter search bar (Filter or search…), choose Prcpart, pick the assembly and click Apply (1), then click its number in the PrcPart column. (Typing straight into the bar without choosing Prcpart searches another field, such as OEM Part.)
- In the left menu, click BOM DATA to expand it, then BOM Overview (n), where n is the number of components.
- Click Tree View for <part> at the top to open the tree, if it isn't already (Cetec remembers whether you left it open). The tree shows the structure; click a circle to expand or collapse a node, or Expand / Collapse Tree for everything.
- Scroll down to the table under BOM Overview for Current Revision for each component's quantity, cost and other details. Change Build Qty and click Set to see quantities for a larger build.
-
Add revisions and labor plans
- Open the assembly's part record and click Revisions in its left menu.
- To add a revision, type its name in Create New Revision and click Create. Cetec shows New Revision Created. The new revision starts with a copy of the current revision's components, so you only change what differs.
- In the revisions table:
- Edit BOM in the BOM column opens that revision's Edit Revision BOM screen (change its components as in Add the components); (Compare) under it compares it with another BOM.
- Labor Plan opens that revision's labor plan, where you set its work locations and operations.